Sonyks

Sonyks is a guided wave ultrasonic testing system designed for rapid long-range screening of pipelines and other structures.
By transmitting low-frequency guided waves along the component, Sonyks can identify areas of potential corrosion or cross-sectional loss from a single test location.
The system combines portable field hardware, modular collars and transducers, intuitive data acquisition, and analysis tools for efficient inspection planning and screening.
Features
- Long-range guided wave ultrasonic screening
- Rapid pipeline corrosion assessment
- Inspection from a single test location
- Modular collars for multiple pipe diameters
- Portable field deployment
- Intuitive acquisition and analysis workflow
- Suitable for insulated and difficult-access piping
- Supports repeatable monitoring inspections
Specifications
General
- NDT method—Guided Wave Ultrasonic Testing / Long-Range Ultrasonic Testing
- Primary application—Long-range, medium-range and short-range corrosion screening of pipelines and piping from a single test location
- Dimensions—355 x 288 x 127 mm (14.0 x 11.3 x 5.0 in)
- Weight—7.2 kg (15.9 lb) with 1 battery
- Power requirements—100-240 VAC, 50-60 Hz
- Power supply—Direct VAC or onboard batteries
- Battery type—10.8 V Li-ion rechargeable batteries, DOT compliant, hot-swappable
- Battery typical life—6-8 hours
- Video output—HDMI
- Transmit channels—40
- Receive channels—40
- Transmitter frequency range—5-260 kHz
- Standard output voltage—200 V peak-to-peak
- Receiving gain range—Up to 100 dB
- Maximum sample range
- —365 m longitudinal in pulse-echo
- —200 m torsional in pulse-echo
- —125 ms in instrument suite
- Maximum number of averages—128
- Focusing options—C-scan imaging and time-delay focusing
- Display
- —26.4 cm (10.4 in) LED touchscreen
- —anti-reflective coating
- —oleophobic coating
- —3 mm chemically strengthened glass
- —optically bonded LCD and touchscreen
- —passive backlight enhancement
- Software options
- —Sonyks GO on instrument
- —Sonyks PRO optional laptop control
- Laptop connectivity—Optional Wi-Fi or Gigabit Ethernet
- Storage—200 GB SSD
- Cooling—Sealed with internal fan
- Onboard pump—60 PSI maximum pressure
- Collar pressure monitoring—Yes
- GPS accuracy—2.5 m (8.2 ft)
- Transduction compatibility—Magnetostrictive and piezoelectric transducer compatibility
- Supported rings—Sonyks Piezo and Magneto tools, Teletest and other commercial PZT rings
- Probe recognition and setup—Automatic with Sonyks tooling, including ring type, size, serial number, pipe orientation and angular orientation
- Automated self-check—Onboard capacitance testing
- Piezo frequency range—20-80 kHz broadband collection
- Piezo pipe size range
- —NPS 6-36 in / DN 150-900 single collar
- —NPS 26-72 in / DN 650-1800 dual collar
- Piezo maximum surface temperature—120 C (248 F)
- Magneto frequency range
- —64 kHz test range 54-74 kHz
- —128 kHz test range 118-138 kHz
- —32 kHz test range 22-42 kHz available on request
- Magneto pipe size range—NPS 1.5, 2, 3, 4, 6 and 8 in / DN 40, 50, 80, 100, 150 and 200
- Magneto maximum surface temperature—80 C (176 F), 120 C (248 F) short term
- Teletest pipe size range
- —NPS 6-24 in / DN 150-600 single collar
- —NPS 26-52 in / DN 650-1300 dual collar
- —NPS 56-76 in / DN 1400-1900 triple collar
- Teletest frequency range—20-80 kHz depending on spacing and wave mode
- Teletest maximum surface temperature
- —120 C (248 F) standard
- —240 C (464 F) high temperature
- Guided wave standards—ISO 18211 and Federal Pipeline Safety Regulations 49 CFR 192.921 Appendix F referenced for Sonyks software workflow